Accel Stator Rotor - 32 Amp Heavy Duty

Share
Heavy Duty Stator Rotor for Powerful Performance.
In stock
Barcode
743047415320
SKU
152100
328.00€ 264.52€
ACCEL Motorsports Lectric stator rotors are made for high vibration and daily drive abuse. The magnets are enclosed by stainless steel to protect against dislodging, and a super thick housing and splines eliminate the possibility of cracking. Heavy duty design is good for stock and modified applications. The perfect complement to our Lectric Stators! Stator Rotor, Lectric, 32 Amp, Harley-Davidson.
Stator Rotor - 32 Amp - Harley Davidson - Heavy DutyACCEL Motorsports Lectric stator rotors are made for high vibration and daily drive abuse.

Charging Problems

Check the Stator:

  1. Disconnect the regulator from the stator at the terminal inside the crankcase.
  2. Check for continuity between either stator pin and the crankcase. Continuity indicates that the stator is grounded and needs to be replaced.
  3. Check the resistance between the stator pins. A reading of 0.1 to 0.2 ohms should be present. A lower reading requires that the stator be replaced.

Check the Output:

  1. Again disconnect the regulator, and connect a voltmeter set to AC volts across the stator terminals. With the engine running at 2000 rpm, there should be a reading of 32-40 AC volts. The output will increase or decrease 16-20 AC volts for every 1000 rpm.

Check the Current Draw:

  1. With all accessories, ignition, and headlamp high beam turned on, read the current draw.
  2. The current draw should be at least 3.5 Amps lower than the output listed in the SPECIFICATIONS section of the Harley-Davidson service manual. You may have too many accessories drawing power for the system to handle.

How Do I Polarize My Generator?

  1. A generator that is not polarized will burn relay points, cause a dead battery, or damage to the generator.
  2. Momentarily touch a jumper wire between the BAT and GEN terminals on the generator.
Write Your Own Review
You're reviewing:Accel Stator Rotor - 32 Amp Heavy Duty
Your Rating
Customer Questions
How do I check for charging problems with the Stator?
To check for charging problems with the Stator, follow these steps: Disconnect the regulator from the stator, check for continuity between stator pins and the crankcase, check resistance between stator pins, and check the output with a voltmeter set to AC volts.
How do I polarize my generator?
To polarize your generator, follow these steps: Momentarily touch a jumper wire between the BAT and GEN terminals on the generator to prevent burning relay points, dead battery, or damage to the generator.
How do I check for charging problems with the Stator?
To check for charging problems with the Stator, follow these steps: Disconnect the regulator from the stator, check for continuity between stator pins and the crankcase, check resistance between stator pins, and check the output with a voltmeter set to AC volts.
How do I polarize my generator?
To polarize your generator, follow these steps: Momentarily touch a jumper wire between the BAT and GEN terminals on the generator to prevent burning relay points, dead battery, or damage to the generator.